IOD-120 ISA 120-Channel Digital I/O Card

120-channel buffered digital input/output card for ISA-bus computers

ACCES: Committed to Service

We're here to help!

Let our amazing support staff help you with questions: whether finding the right model for you, or technical support on using the product - or figuring out what's wrong - we have the expertise to help you. Use it!

Call, E-Mail, or Chat, Today!

FEATURES

  • 120 buffered TTL digital I/O channels on the ISA bus
  • Four- and eight-bit groups independently programmable for input or output
  • Tristate transceiver buffers with software-controlled direction and enable
  • Outputs source 15 mA and sink 24 mA; optional 64 mA sinking on request
  • 1 kΩ pull-down resistors for defined I/O bias
  • 5 50-pin I/O headers with alternating signal and ground conductors
  • External interrupt support with jumper-selectable IRQ levels
  • Ports default to inputs at power-up or reset
  • Designed and manufactured in the USA
Last updated on November 5, 2026, 8:48 am

$339.00

In Stock
SKU: IOD-120 Categories: , Tags: ,

Description

The IOD-120 provides 120 buffered TTL digital input/output channels for ISA-bus computers. Its 5 type 8255-5 programmable peripheral interface devices each provide three 8-bit ports, designated A, B, and C. Each port can be programmed for input or output, and Port C can be divided into two independently configured 4-bit groups.

Buffered Digital I/O

The card supports Mode 0 of the 8255 interface. Bidirectional LS245 transceivers provide input hysteresis and additional output drive, with software-controlled direction. Standard outputs source 15 mA and sink 24 mA; a 64 mA sink-current option is available on request. The card incorporates 1 kΩ pull-down resistors on the I/O lines.

Software can enable or disable the I/O buffers. At power-up or reset, the ports are configured as inputs to prevent unintended output states. Configure the PPI control registers before using the card.

External Interrupts

Each 24-bit I/O group supports an external interrupt signal and an interrupt-enable control using two of its I/O lines. Interrupt levels IRQ2–IRQ7, IRQ10–IRQ12, IRQ14, and IRQ15 are selected by jumpers.

Connections and Addressing

5 50-pin on-board headers connect the I/O signals to ribbon cables that pass through openings in the mounting bracket. Cable strain relief is provided. Ground conductors alternate with signal conductors to reduce crosstalk. The connection scheme supports compatible industry-standard solid-state I/O module racks and screw-terminal panels.

The base I/O address is selected by DIP switches. The card occupies 32 bytes of I/O address space. Bus-derived +5 VDC is available at the I/O connectors; use an external 1 A fast-blow fuse when supplying external circuitry.

96-Channel Configuration

A jumper can configure the IOD-120 for 96-channel operation, reducing its I/O address-space requirement from 32 to 16 bytes.

Modified-COTS (MCOTS) Customization

ACCES can tailor any standard product to your precise requirements — electrical, mechanical, firmware, environmental, or connector-level. Common MCOTS options include alternate I/O ranges, isolation enhancements, firmware changes, private labeling, conformal coating, extended temperature operation, ruggedized enclosures, and military-grade components. If this product is close but not a perfect fit, our engineering team can deliver a rapid-turn MCOTS variant with minimal NRE and dependable, Made-in-USA quality.

Interface and Digital I/O

Bus ISA
Digital I/O channels 120
PPI devices 5 type 8255-5 devices; three 8-bit ports per device
Direction control Programmable in 8-bit ports; Port C can be split into two 4-bit groups
Operating mode 8255 Mode 0
I/O buffers Bidirectional LS245 tristate transceivers; software-controlled enable
I/O line bias 1 kΩ pull-down resistors
Base address selection DIP switches
Address-space requirement 32 bytes; 16 bytes in 96-channel mode
Interrupt levels IRQ2–IRQ7, IRQ10–IRQ12, IRQ14, IRQ15; jumper selected
I/O connectors 5 50-pin headers

Digital Inputs

Logic high 2.0 to 5.0 VDC
Logic low −0.5 to 0.8 VDC
Input load, high +20 µA
Input load, low −200 µA

Digital Outputs

Logic high 2.5 VDC minimum; source 15 mA
Logic low 0.5 VDC maximum; sink 24 mA
Optional sink current 64 mA, on request

Power and Environmental

Power required +5 VDC at 200 mA typical
Power output +5 VDC from computer bus; external 1 A fast-blow fuse recommended
Card length 13.1 inches (333 mm)
Operating temperature 0 to 60 °C
Storage temperature −50 to 120 °C
Humidity 0 to 90% RH, non-condensing

120-channel buffered digital input/output card for ISA-bus computers.

ModelDescriptionPrice (USD)
IOD-120 ISA 120-Channel Digital I/O Card

The IOD-120 provides 120 buffered TTL digital input/output channels for ISA-bus computers. Its 5 type 8255-5 programmable peripheral interface devices each provide three 8-bit ports, designated A, B, and C. Each port can be programmed for input or output, and Port C can be divided into two independently configured 4-bit groups.

Buffered Digital I/O

The card supports Mode 0 of the 8255 interface. Bidirectional LS245 transceivers provide input hysteresis and additional output drive, with software-controlled direction. Standard outputs source 15 mA and sink 24 mA; a 64 mA sink-current option is available on request. The card incorporates 1 kΩ pull-down resistors on the I/O lines.

Software can enable or disable the I/O buffers. At power-up or reset, the ports are configured as inputs to prevent unintended output states. Configure the PPI control registers before using the card.

External Interrupts

Each 24-bit I/O group supports an external interrupt signal and an interrupt-enable control using two of its I/O lines. Interrupt levels IRQ2–IRQ7, IRQ10–IRQ12, IRQ14, and IRQ15 are selected by jumpers.

Connections and Addressing

5 50-pin on-board headers connect the I/O signals to ribbon cables that pass through openings in the mounting bracket. Cable strain relief is provided. Ground conductors alternate with signal conductors to reduce crosstalk. The connection scheme supports compatible industry-standard solid-state I/O module racks and screw-terminal panels.

The base I/O address is selected by DIP switches. The card occupies 32 bytes of I/O address space. Bus-derived +5 VDC is available at the I/O connectors; use an external 1 A fast-blow fuse when supplying external circuitry.

96-Channel Configuration

A jumper can configure the IOD-120 for 96-channel operation, reducing its I/O address-space requirement from 32 to 16 bytes.

$339.00